• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Tabulated Data.
Figure 1. Wiring diagram.

Maintenance Manual For Crusher, Roll: Diesel And Electric Driven, Pneumatic Tires, 75 Ton Per Hour - Vol1 Page Navigation
  1    2  3  4    5    6    7    8  
img
.
Pressure .............................. 100 psi (pounds per
(15) Feeder, return (under) conveyor, and rotary
square inch)
elevator motors.
(19) Adjustments.
Manufacturer........................ General Electric Co.
Fan Belts ............................. in. (inch) (es) de-
Model ................................... 5KG215BG202
flection between pul-
Type .................................... KG
leys on long side
Horsepower .......................... 5
Drive belts (electric motor) ... 1/2 in. deflection between
Revolutions per minute ....... 1,745
pulleys
Volt ..................................... 208-220/440
Main drive belt ..................... 1 to 1 1/2 in. deflection
Phase .................................. 3
between pulleys
Cycle ................................... 60
Crusher rolls springs............. 23 in. spring length
Amperes ............................. 14.2/7.1
Intake valves (hot) .............. 0.020 in.
Time rating........................... Continuous
Exhaust valves (hot) ........... 0.024 in.
(16) Vibrating screen motor.
Generator regulator:
Manufacturer........................ General Electric Co.
Cutout relay air gap ......... 0.048 in.
Model .................................. 5KG4284B2
Cutout relay point opening 0.035 in.
Type .................................... KG
Cutout relay closing
Horsepower ......................... 15
voltage ...................... 25-27 v (volts)
Revolutions per minute ........ 1,755
Current regulator air gap.. 0.115 in.
Volt ..................................... 208-220/440
Current regulator current
Phase .................................. 3
setting ........................ 38 to 42 amp (amperes)
Cycle ................................... 60
Voltage regulator air gap . 0.084 in.
Amperes .............................. 40.8/20.4
Voltage regulator closing
Time rating .......................... Continuous
voltage ...................... 27.5-29.5 v
(17) Main (feed) conveyor motor.
(when adjusting set at
Manufacturer........................ General Electric Co.
middle of range) 28.5 v
Model .................................. 5KG4256B2
(20) Nut and bolt torque data.
Type .................................... KG
Intake manifolds .................. 50-55 ft-lb (foot-
Horsepower ......................... 10
pounds)
Revolutions per minute ........ 1,745
Exhaust manifolds ............... 50-55 ft-lb
Volt ...................................... 208-220/440
Fuel injectors ....................... 14-16 ft-lb
Phase .................................. 3
Fuel line connector screws .. 420 in-lb (inch-pounds)
Cycle.................................... 60
Wheel bearing adjusting nut . 50 ft-lb
Amperes ............................. 27.4/13.7
Wheel bearing outer locknut 250-400 ft-lb
Time rating........................... Continuous
Inner and outer wheel nuts .. 500-600 ft-lb
(18) Tires.
Size ..................................... 11:00-15
(21) Practical wiring diagram.  The practical wiring
Type..................................... LPT Nylon
diagram of the electrical system is shown on
Number of ply ...................... 20 ply rating
figure 1.
AGO 8157A
5


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.