CONTROL PANELS AND WIRING HARNESS REPAIR
INSTRUCTIONS
Section I. MAGNETIC STARTER ASSEMBLY
211. Magnetic Starter Assembly Cleaning,
I n s p e c t i o n , and Repair
The magnetic starter assembly is mounted on
a. Cleaning. Clean all parts with an ap-
the panel in the main control box. The starter
proved cleaning solvent and dry thoroughly.
i s energized by an electrical current which is
b . I n s p e c t i o n a n d R e p a i r . Inspect all parts
controlled by a pushbutton and circuit breaker.
for wear and damage. Repair or replace worn
o r damaged parts.
210. Magnetic Starter Assembly Removal
2 1 2 . Magnetic Starter Assembly Reassembly
a n d Disassembly
a n d Installation
a. Removal.
a . Reassembly. Refer to figure 60, and reas-
semble the magnetic starter assembly in the
(1) Remove the power cables (TM 5-
r e v e r s e order.
3820-205-10/1).
b . Installation.
( 2 ) Remove the magnetic starter (TM 5-
(1) Install the magnetic starter (TM 5-
3820-205-20/1).
3820-205-20/1).
( 2 ) Install the power cables (TM 5-3820-
205-10/1).
assemble the magnetic starter assembly.
Figure 60. Magnetic starter assembly, exploded view.
AGO 8498A