CHECK VALVE AND BYPASS VALVE
REMOVE SHUTOFF HOUSING

Technical Manual For Compactor, High Speed, Tamping Self-Propelled Page Navigation
  428    429    430    431    432  433  434    435    436    437    438  
img
3208 INDUSTRIAL AND MARINE ENGINES
DISASSEMBLY AND ASSEMBLY
CHECK VALVE AND BYPASS VALVE
INSTALL CHECK VALVE AND BYPASS VALVE
1. Install the bypass valve (2) and spring (1) in
the pump housing.
2. Install the cover (3) on the pump housing.
Be sure the spring (I) is in the bore in the
lever.
3. Install the seven bolts that hold the cover to
the pump housing.
4. Install a new gasket (5) on the cover. Install
a new check valve (4) in the flange assembly
(6). Put the flange assembly in position on
the cover.
5. Install a new gasket (7) on the flange
assembly. Install flange (8) on the flange as-
sembly with the bolts that hold them to the
cover.
end by:
a) install fuel injection pump housing
and governor
18