Figure 30. Battery box, exploded view.
screws securing the cutout relay contact bracket to the cutout relay and raise or lower the cutout relay contact bracket
until the specified air gap is obtained. Secure the adjustment by tightening the two screws.
(g) Push down on the voltage regulator armature (2, fig. 33) until the voltage regulator contact point barely
touches the air gap adjusting screw. Measure the air gap between the coil core and the armature of the
voltage regulator. Do not measure
AGO 8156A