img
HYDRAULIC TANK
MAINTENANCE:
CHECK HYDRAULIC TANK LEVEL dally with machine
level, blade lowered and engine off. The level gauge is
mounted on the forward surface of the hydraulic tank on
the operator's left.  Refill as necessary, adding proper
fluid (refer to LUBRICANTS SPECIFICATION CHART).
Hydraulic Oil Level Gauge
CHANGE HYDRAULIC FILTER every 200 hours.
1. Clean all dirt from around filter head, remove
capscrews and lift off head.
Caution: Care must be taken to replace all parts
in proper sequence.
2. Remove coil spring and filter by-pass valve
assembly.
Removing By Pass Valve Assembly