• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 49. Fan and water pump, removal and installation.
Figure 51. Thermostat and housing, installed view.

Maintenance Manual For Crusher, Roll: Diesel And Electric Driven, Pneumatic Tires, 75 Ton Per Hour - Vol2 Page Navigation
  63    64    65    66    67  68  69    70    71    72    73  
img
. . . . . . . .
Figure 50. Radiator shroud, removal and installation.
(2)
Install the fan (par. 105).
(3)
Install the engine hood (par. 98).
(4)
Fill the cooling system (TM 5-3820-205-10/2).
107. Thermostat and Housing
a.
Removal.
(1)
Drain the cooling system (TM 5-3820-205-10/2).
(2)
Remove the thermostat and housing as instructed on figure 51.
b.
Cleaning and Inspection. Clean and inspect the thermostats and housing. Replace if necessary.
c.
Test. Place the thermostat and suitable thermometer in a pan or pail of water and heat slowly.
The thermostat should start to open at 165-170 F. and be fully open at 180-185 F. Replace a defective
thermostat.
d.
Installation.
(1)
Install the thermostats in reverse of instructions on figure 51.
(2)
Fill the cooling system (TM 5-3820-205-10/2).
108. Water Manifold
a.
Removal.
(1)
Drain the cooling system (TM 5-9820-205-10/2).
(2)
Remove the thermostats and housing (par. 107).
(3)
Remove the water manifold as instructed on figure 40.
b.
Cleaning and Inspection.  Clean and inspect the water manifold for any damage.
Replace if
necessary.
c.
Installation.
(1)
Install the water manifold in reverse of instructions on figure 40.
(2)
Install the thermostats and housing (par. 107).
(3)
Fill the cooling system (TM 5-3820-205-10/2).